The wind sensor generates a pulse sequence that depends on the speed of the wind turbine.
the Wind sensor with pulse output is connected to a digital input of an extension. It is important that the input is defined as a frequency counter. To do this, simply mark the input and activate the Frequency counter checkbox in the properties.
Note that only the inputs of an extension with a frequency counter function can be used if a wind sensor with a pulse output is used.
Stable plastic housing, diameter x height = 125 x 117mm, protection class IP54.
Ambient temperature -15 ° C to + 60 ° C. Fastening with the enclosed plastic mounting bracket.
With a 5 meter test lead connected.
Technical details
- Measuring range: 5… 120 km / h
- Switching contact: reed contact 5-30V
- Exit: 2 Imp./s per revolution
- 5m connection cable
- 2 pulses per revolution
- Formula: pulses per second = 3x wind speed. -2
Example:
Wind speed m / s 2
Wind speed km / h = 7.2
Revolutions 1 / min = 120
Pulses = 4